How to Reset a Matrix Switcher When the Web GUI Password Isn’t Working
If you’re unable to log into the Web GUI of a matrix switcher due to an incorrect or unknown password, the device can still be reset using either network communication or RS-232, depending on its accessibility.
Option 1: Reset via Network (Device Still Reachable)
Use this method if the matrix switcher is still accessible on the network.
Step 1: Verify Network Access
Confirm the device is reachable by checking one or more of the following:
- Web GUI loads (even if login fails)
- Successful ping to the device’s IP address
- Device appears in network scan tools
Step 2: Install a Communication Utility
Download and install a terminal application that supports Telnet or TCP/IP communication, such as:
- PuTTY
Step 3: Obtain the Device API Commands
- Refer to the product manual for the API or control command list
- If not available, request the API documentation from technical support
Step 4: Connect and Send the Reset Command
- Open a Telnet or TCP/IP session to the device
- Send the factory reset or password reset command as defined in the API
Required Information for Network Connection
- Device IP address
- Telnet port number or TCP/IP port number
- Reset command syntax from the API documentation
Option 2: Reset via RS-232 (Device Not Reachable on Network)
Use this method if the device is no longer accessible over the network.
Step 1: Connect via RS-232
- Connect a serial cable between the matrix switcher and your PC
- Use a USB-to-RS-232 adapter if your computer does not have a serial port
Step 2: Install a Serial Communication Tool
Download and install a serial terminal application, such as:
- Docklight
- PuTTY (Serial mode)
- Tera Term
Step 3: Obtain the Device API Commands
- Check the product manual for RS-232 control commands
- If unavailable, request the command set from technical support
Step 4: Connect and Send the Reset Command
- Configure the serial connection using the device’s communication settings
- Send the reset command as defined in the API
Required Information for RS-232 Connection
- Baud rate
- Data bits
- Stop bits
- Parity (check bit)
- COM port number (assigned after cable connection)
After the Reset
- The matrix switcher will return to factory default settings
- Network configuration and credentials may be reset
- Reconfigure the device and set a new Web GUI password
Notes
- Always use the official API commands for the specific model
- Contact technical support if the device does not respond to reset commands